VCU_ENC_AXI_PROT (VCU_SLCR) Register

Zynq UltraScale+ Devices Register Reference (UG1087)

Document ID
UG1087
Release Date
2024-03-13
Revision
1.10

VCU_ENC_AXI_PROT (VCU_SLCR) Register Description

Register NameVCU_ENC_AXI_PROT
Offset Address0x0000000050
Absolute Address 0x00A0040050 (VCU_SLCR)
Width32
TypemixedMixed types. See bit-field details.
Reset Value0x00BB3BB3
DescriptionCaution! The fields in this regsiter must not be changed while the VCU is active and AXI traffic is being produced. It is recommended that this field only change during 'idle/inactive' periods of the VCU

VCU_ENC_AXI_PROT (VCU_SLCR) Register Bit-Field Summary

Field NameBitsTypeReset ValueDescription
awqos123:20rwNormal read/write0xBAXI Write QoS Field Port 1
arqos119:16rwNormal read/write0xBAXI Read QoS Field Port 1
Reserved15:14razRead as zero0x0reserved
arprot113rwNormal read/write0x1AXI Read Protection Field Port 1
awprot112rwNormal read/write0x1AXI Write Protection Field Port 1
awqos011:8rwNormal read/write0xBAXI Write QoS Field Port 0
arqos0 7:4rwNormal read/write0xBAXI Read QoS Field Port 0
Reserved 3:2razRead as zero0x0reserved
arprot0 1rwNormal read/write0x1AXI Read Protection Field Port 0
awprot0 0rwNormal read/write0x1AXI Write Protection Field Port 0