Field Name | Bits | Type | Reset Value | Description |
cfg_desired_ven_msg_ven_id | 31:16 | rwNormal read/write | 0x0 | Vendor Defined Message Type 0/1 (Message Code 0x7e & 0x7f) Vendor ID used to perform Vendor ID-specific message filtering. |
cfg_desired_ven_msg_ven_inv | 15 | rwNormal read/write | 0x0 | Selects how to apply Vendor ID-specific filtering. |
cfg_desired_ven_msg_en | 14 | rwNormal read/write | 0x0 | |
cfg_enable_oth_msg_fwd | 13 | rwNormal read/write | 0x0 | When 1, received PCIe messages with msg_code[7:4] not matching 0x1, 0x2, 0x3, 0x5, or 0x7 (other message types) will be forwarded to the AXI Master Interface. When 0 such messages will be silently dropped and not forwarded. |
Reserved | 12:8 | roRead-only | 0x0 | |
cfg_enable_ven_msg_fwd | 7 | rwNormal read/write | 0x0 | When 1, received PCIe messages with msg_code[7:4] not matching 0x1, 0x2, 0x3, 0x5, or 0x7 (other message types) will be forwarded to the AXI Master Interface. When 0 such messages will be silently dropped and not forwarded. |
Reserved | 6 | roRead-only | 0x0 | |
cfg_enable_slt_msg_fwd | 5 | rwNormal read/write | 0x0 | When 1, received PCIe messages with msg_code[7:4] == 0x5 (such as Set Slot Power Limit) will be forwarded to the AXI Master Interface. When 0 such messages will silently be dropped and not forwarded. |
Reserved | 4 | roRead-only | 0x0 | |
cfg_enable_err_msg_fwd | 3 | rwNormal read/write | 0x0 | When 1, received PCIe messages with msg_code[7:4] == 0x3 (such as ERR_COR, ERR_NONFATAL, ERR_FATAL) will be forwarded to the AXI Master Interface. When 0 such messages will be silently dropped and not forwarded. |
cfg_enable_int_msg_fwd | 2 | rwNormal read/write | 0x0 | When 1, received PCIe messages with msg_code[7:4] == 0x2 (Assert_INT[A,B,C,D], Deassert_INT[A,B,C,D]) will be forwarded to the AXI Master Interface. When 0 such messages will be silently dropped and not forwarded. |
cfg_enable_pm_msg_fwd | 1 | rwNormal read/write | 0x0 | When 1, received PCIe messages with msg_code[7:4] == 0x1 (Power Management messages such as PME_Turn_Off, PME_TO_ACK) will be forwarded to the AXI Master Interface. When 0 such messages will be silently dropped and not forwarded. |
Reserved | 0 | roRead-only | 0x0 | |