| Field Name | Bits | Type | Reset Value | Description |
| cnta7_over_err | 15 | wtcReadable, write a 1 to clear | 0x0 | Overflow for counter that is clocked by clock A. |
| mon7_err | 14 | wtcReadable, write a 1 to clear | 0x0 | CLK7 was not within the acceptable range |
| cnta6_over_err | 13 | wtcReadable, write a 1 to clear | 0x0 | Overflow for counter that is clocked by clock A. |
| mon6_err | 12 | wtcReadable, write a 1 to clear | 0x0 | CLK6 was not within the acceptable range |
| cnta5_over_err | 11 | wtcReadable, write a 1 to clear | 0x0 | Overflow for counter that is clocked by clock A. |
| mon5_err | 10 | wtcReadable, write a 1 to clear | 0x0 | CLK5 was not within the acceptable range |
| cnta4_over_err | 9 | wtcReadable, write a 1 to clear | 0x0 | Overflow for counter that is clocked by clock A. |
| mon4_err | 8 | wtcReadable, write a 1 to clear | 0x0 | CLK4 was not within the acceptable range |
| cnta3_over_err | 7 | wtcReadable, write a 1 to clear | 0x0 | Overflow for counter that is clocked by clock A. |
| mon3_err | 6 | wtcReadable, write a 1 to clear | 0x0 | CLK3 was not within the acceptable range |
| cnta2_over_err | 5 | wtcReadable, write a 1 to clear | 0x0 | Overflow for counter that is clocked by clock A. |
| mon2_err | 4 | wtcReadable, write a 1 to clear | 0x0 | CLK2 was not within the acceptable range |
| cnta1_over_err | 3 | wtcReadable, write a 1 to clear | 0x0 | Overflow for counter that is clocked by clock A. |
| mon1_err | 2 | wtcReadable, write a 1 to clear | 0x0 | CLK1 was not within the acceptable range |
| cnta0_over_err | 1 | wtcReadable, write a 1 to clear | 0x0 | Overflow for counter that is clocked by clock A. |
| mon0_err | 0 | wtcReadable, write a 1 to clear | 0x0 | CLK0 was not within the acceptable range |