CONFIG_REG0 (PSSYSMON) Register Description
| Register Name | CONFIG_REG0 |
|---|---|
| Offset Address | 0x0000000100 |
| Absolute Address | 0x00FFA50900 (AMS_PS_SYSMON) |
| Width | 16 |
| Type | rwNormal read/write |
| Reset Value | 0x00000000 |
| Description | Configuration, Reg 0. |
Channel and sampling modes. Refer to SysMon Chapter and UG580 for more information. PS SysMon does not interface to external signals/mux.
CONFIG_REG0 (PSSYSMON) Register Bit-Field Summary
| Field Name | Bits | Type | Reset Value | Description |
|---|---|---|---|---|
| averaging | 13:12 | rwNormal read/write | 0x0 | Averaging mode enable and set. 0: no averaging. 1: 16 samples. 2: 64 samples. 3: 256 samples. Applies to sequencer looping. |
| EC | 9 | rwNormal read/write | 0x0 | Reserved. Single sampling is triggered by the AMS.PS_SYSMON_CONTROL_STATUS register. |
| ACQ | 8 | rwNormal read/write | 0x0 | Long Acquisition Settling Time enable. 0: normal. 1: long acquisition time. Applies to single sampling mode of single channel. |
| Reserved | 7:6 | rwNormal read/write | 0x0 | reserved |
| mux_channel | 5:0 | rwNormal read/write | 0x0 | Single-channel Mode. Select the analog sensor channel to measure using bits [5:0]. The analog channels are listed in the PS SysMon and AMS Sensor Channel tables of UG1085. |