ALARM_OT_LOWER (PLSYSMON) Register Description
| Register Name | ALARM_OT_LOWER |
|---|---|
| Offset Address | 0x000000015C |
| Absolute Address | 0x00FFA50D5C (AMS_PL_SYSMON) |
| Width | 16 |
| Type | rwNormal read/write |
| Reset Value | 0x00000000 |
| Description | Over Temperature Alarm Clear Mode and Hysteresis Threshold for the PL |
Over Temperature Alarm Clear Hysteresis Threashold. The over temperature alarm normally is cleared when the measured temperature returns back below the ALARM_OT_UPPER temperature threshold register. When hysteresis is enable, the high temperature alarm is cleared when the measured temperature falls below the value of the [temperature_alarm] value.
ALARM_OT_LOWER (PLSYSMON) Register Bit-Field Summary
| Field Name | Bits | Type | Reset Value | Description |
|---|---|---|---|---|
| temperature_alarm | 15:1 | rwNormal read/write | 0x0 | Over Temperature Alarm Clear Hysteresis Threashold Value |
| threshold_mode | 0 | rwNormal read/write | 0x0 | Over Temperature Alarm Clear Threshold Mode: 0: hysteresis enabled 1: hysteresis disabled |