ERR_STATUS2 (XMPU_OCM) Register - UG1087

Zynq UltraScale+ Devices Register Reference (UG1087)

Document ID
UG1087
Release Date
2024-03-13
Revision
1.10

ERR_STATUS2 (XMPU_OCM) Register Description

Register NameERR_STATUS2
Offset Address0x0000000008
Absolute Address 0x00FFA70008 (OCM_XMPU_CFG)
Width32
TyperoRead-only
Reset Value0x00000000
DescriptionError Status, Reg 2.

"The first AXI violation is recorded. Once a violation status flag is set in the ISR register, subsequent violations are not recorded. This register is reset by clearing a violation flag in the ISR register."

ERR_STATUS2 (XMPU_OCM) Register Bit-Field Summary

Field NameBitsTypeReset ValueDescription
Reserved31:10roRead-only0x0reserved
AXI_ID 9:0roRead-only0x0Master ID from a poisoned read or write transaction.
Read-only.