APM3_RESULT17 (VCU_SLCR) Register Description

Register NameAPM3_RESULT17
Offset Address0x0000000450
Absolute Address 0x00A0040450 (VCU_SLCR)
Width32
TypemixedMixed types. See bit-field details.
Reset Value0x00000000
DescriptionAPM3_RESULT17

APM3_RESULT17 (VCU_SLCR) Register Bit-Field Summary

Field NameBitsTypeReset ValueDescription
validity_check31roRead-only0x0This signal will toggle in alternate timing window. This is required for safe reading of accumulated read and write latencies parameters which requires more then one APM access. This bit field is read with all the latency related APB registers and this is expected to be same for all those registers.
Reserved30:17razRead as zero0x0reserved
accum_rd_lat116:0roRead-only0x017 MSBs of accumulated read latency for 2nd FIFO over configured timing.