RxBuff0_DW11_Msg_n (CANFD) Register

Versal Adaptive SoC Register Reference (AM012)

Document ID
AM012
Release Date
2023-08-29
Revision
1.3

RxBuff0_DW11_Msg_n (CANFD) Register Description

Register NameRxBuff0_DW11_Msg_n
Relative Address0x0000002134
Absolute Address 0x00FF062134 (CANFD0)
0x00FF072134 (CANFD1)
Width32
TyperoRead-only
Reset Value0x00000000
Description64 dw_11 regs for RxBuffer_0 msgs 0 to 63 at 0x2134, 0x217C, etc (0x48 step)

There are 64 Rx FIFO 0 DW 11 message registers. For CANFD frames, DW 11 includes data bytes 44, 45, 46, 47. (DW 11 not used for CAN) Note: First DW 11 register is at offset 0x2134. Second DW 11 register is at 0x217C; the address stepping is 0x048. Software Driver name: RF0_RB_DW11 Original Bit Field Engineering Name: Data_bytes40

RxBuff0_DW11_Msg_n (CANFD) Register Bit-Field Summary

Field NameBitsTypeReset ValueDescription
DB4431:24roRead-only0Data Byte 44
Software Driver name: DB44
Note: Field name reference: Data_bytes44
DB4523:16roRead-only0Data Byte 45
Software Driver name: DB45
Note: Field name reference: Data_bytes45
DB4615:8roRead-only0Data Byte 46
Software Driver name: DB46
Note: Field name reference: Data_bytes46
DB47 7:0roRead-only0Data Byte 47
Software Driver name: DB47
Note: Field name reference: Data_bytes47