The AIB instances in the interconnect are shown in Table: AIB Instances.

Table 16-17:      AIB Instances

Instance Number

Domain

Master Device

Slave Device

1

LPD

RPU0

LPD interconnect

2

LPD

RPU1

LPD interconnect

3

LPD

RPU through LPD interconnect

DDR through FPD interconnect

4

LPD

LPD interconnect

FPD interconnect (all other FPD slaves)

5

LPD

LPD interconnect

RPU0

6

LPD

LPD interconnect

RPU1

7

LPD

LPD interconnect

USB0

8

LPD

LPD interconnect

USB1

9

LPD

LPD interconnect

OCM

10

LPD

LPD interconnect

M_AXI_HPM0_LPD

11

FPD

FPD interconnect

LPD interconnect (except OCM)

12

FPD

FPD interconnect

LPD interconnect (only to OCM)

13

FPD

FPD interconnect

M_AXI_HPM0_FPD

14

FPD

FPD interconnect

M_AXI_HPM1_FPD

15

FPD

FPD interconnect

GPU