End of Sequence Event

Zynq UltraScale+ Device Technical Reference Manual (UG1085)

Document ID
UG1085
Release Date
2023-12-21
Revision
2.4 English

When a sequencer has completed a loop through all selected channels, it signals the end of sequence (EOS) event. The EOS signal can be generated after the normal rate sequence is done, after the low-rate sampling is done, or after either is done by programming the CONFIG_REG4 [low_rate_eos] bit. For the PL SYSMON, this can be an output on the SYSMONE4 primitive (requires it to be instantiated). For the PS SYSMON, the AMS.ISR_1 [eos] bit asserts and generates an interrupt if enabled.