Measurement Registers in AMS

Zynq UltraScale+ Device Technical Reference Manual (UG1085)

Document ID
UG1085
Release Date
2023-12-21
Revision
2.4 English

The AMS register set includes several measurement registers that are written to by the PS SYSMON unit using the single-channel mode (sequencer off). These voltage measurements are performed using the unipolar sampling circuit with a 0 to 3V range and do not have alarms or minimum/maximum registers.

The AMS measurement register names for each voltage node are listed in Table: Measurement Registers in AMS Register Set, and are accessed starting at memory location 0xFFA5_0060.

Table 9-4:      Measurement Registers in AMS Register Set

Voltage Node

Description

Channel Number

Seq
Bit

VCC_PSPLL

System PLLs voltage.

48

0

VCC_PSBATT

Battery voltage.

51

3

VCCINT

PL internal voltage.

54

6

VCCBRAM

PL block RAM voltage.

55

7

VCCAUX

PL VAUX voltage.

56

8

VCC_PSDDR_PLL

PS DDR I/O PLLs {0:5} voltage.

57

9

VCC_DDRPHY_REF

PS DDR I/O buffer voltage.

58

10

VCC_PSINTFP_DDR

PS DDR controller voltage.

63

15

Notes:

1.PSSYSMON.SEQ_BASIC_MONITOR_CHANNEL0 register for low-rate sequence assignment.