The following ports are used to calibrate the IO Delays that the RGMII interface uses for Versal devices. Refer to AR 000033647 to calibrate the values of these ports.
Signal Name | Direction | Description |
---|---|---|
idelay_cnt_val[4:0] | In | CNTVALUEIN input of all the IDELAYS that are driven by rgmii_rxd[3:0] and rgmii_rx_ctl |
idelay_load | In | LOAD input of all the IDELAYS that are driven by rgmii_rxd[3:0] and rgmii_rxc |
odelay_cnt_val[4:0 | In | CNTVALUEIN input of the ODELAY that drives rgmii_tx_clk |
odelay_load | In | LOAD input of the ODELAY that drives rgmii_tx_clk |