Graph name: Samples - 2023.2 English

Vitis Libraries

Release Date
2023-12-20
Version
2023.2 English

This graph is used to compute the delay in reception for every transducer. It sums also the delay in transmission to obtain the valid samples for the interpolation.

  • Graph Inputs:
    • image_points_from_PL_2: Result of Image Points;
    • delay_from_PL: Result of Delay;
    • xdc_def_positions: X-Y-Z vector which represents the positions of our transducers in the probe;
    • sampling_frequency: The sampling frequency of the probe;
  • Graph Outputs:
    • samples_to_PL: A vector which represents our valid entries in the rf-data vector;