DDS/Mixer Configuration Parameters - 2024.1 English

Vitis Libraries

Release Date
2024-08-06
Version
2024.1 English

For the DDS/Mixer library element, use the following list of configurable parameters and default values:

Table 66 DDS/Mixer Configuration Parameters
Name Type Default Description
DATA_TYPE typename cint16 Data Type.
WINDOW_VSIZE unsigned 256 Input/Output window size.
MIXER_MODE unsigned 2

The mode of operation of the dds_mixer.

0: dds only

1: dds plus single data channel mixer

2: dds plus two data channel mixer, for symmetrical carrier

P_API unsigned 0

0: window,

1: stream

UUT_SSR unsigned 1 Super Sample Rate SSR parameter. Defaults to 1.
NITER unsigned 16 See Common Configuration Parameters
DIFF_TOLERANCE unsigned 0 See Common Configuration Parameters
INITIAL_DDS_OFFSET unsigned 0 Initial DDS offset.
DDS_PHASE_INC unsigned 0xD6555555 DDS Phase Increment.
DATA_STIM_TYPE unsigned 0 See STIM_TYPE in Common Configuration Parameters
ROUND_MODE unsigned 0 See Common Configuration Parameters
SAT_MODE unsigned 1 See Common Configuration Parameters
USE_PHASE_RELOAD unsigned static phase

0: ‘static phase’

1: ‘reload phase offset’

Additionally, for the DDS/Mixer library element that uses LUTs, an additional template parameter is available:

Name Type Default Description
SFDR unsigned 90 specifies the expected Spurious Free Dynamic Range that the useR expects from the generated design.