The Vector Concat block concatenates two or more inputs of type vector. The output is cast to an unsigned value with the binary point at zero.
Description
Super Sample Rate (SSR): This configurable GUI parameter is primarily used to control processing of multiple data samples on every sample period. This block enables 1-D vector data support for the primary block operation.
The Vector Reinterpret block provides capabilities that can extend the functionality of the Vector Concat block.
Block Interface
The block has n input ports, where n is a value
between 2 and 1024, inclusively, and one output port. The first and last input ports
are labeled hi
and low
, respectively. Input ports between these two ports are not
labeled. The input to the hi
port occupies the most significant
bits of the output, and the input to the lo
port occupies the least
significant bits of the output.
Block Parameters
Double-click the icon in your Simulink® model to open the Block Parameter dialog box.
Parameters specific to this block are as follows:
- Number of Inputs: Specifies number of inputs, between 2 and 1024, inclusively, to concatenate together.
Other parameters used by this block are explained in the topic Common Options in Block Parameter Dialog Boxes.
The Vector Concat block does not use a Xilinx LogiCORE™ ™.