When the controller is in the Diagnostic Scan state, the controller reports errors immediately after detection of the error condition. After detecting an error, the controller interrupts the scan to report the error through the Monitor Interface. The controller does not resume the scan until all errors in the current frame are reported. Hence, it is important that when this feature is executing, there is not any unnecessary back-pressure occurring on the Monitor Interface. The following scenarios exist:

Diagnosis: ECC-based error – Uncorrectable [cannot identify location or number of bits in error]

RI XX Reserved Information
ECC ECC error detected
TS {8-digit hex value} Timestamp
PA {n-digit hex value} PFA of Detected Error. n = 7 for UltraScale and 8 for UltraScale+.
LA {n-digit hex value} LFA of Detected Error. n = 7 for UltraScale and 8 for UltraScale+.

The Detection Report PA includes both the SLR number and PFA address. The PA is formatted to match the PFA error injection command format without the Word and Bit fields. For more information, see “Error Injection Using PFA” in Table 1.

UltraScale PA = 0sst trrr rrrc cccc cccc cmmm mmmm
UltraScale+ PA = 00ss 0ttt rrrr rrcc cccc cccc 
mmmm mmmm

The Detection Report LA includes both the SLR and LFA address. The LA is formatted to match the LFA error injection command format without the Word and Bit fields and with the most significant nibble zeroed out. For more information, see “Error Injection Using LFA” in mji1696498882949.html#mji1696498882949__table_csk_1wz_qyb.

UltraScale = 0000 0000 0ssL LLLL LLLL LLLL LLLL
UltraScale+ = 0000 0000 0000 ssLL LLLL LLLL LLLL LLLL

Diagnosis: ECC-based error – Correctable

RI XX Reserved Information
ECC ECC error detected
TS {8-digit hex value} Timestamp
PA {n-digit hex value} PFA of Detected Error. n = 7 for UltraScale and 8 for UltraScale+.
LA {n-digit hex value} LFA of Detected Error. n = 7 for UltraScale and 8 for UltraScale+.
WD {2-digit hex value} BT {2-digit hex value} Word and Bit of the Detected Error

The Detection Report PA includes both the SLR number and PFA address. The PA is formatted to match the PFA error injection command format without the Word and Bit fields. For more information, see “Error Injection Using PFA” in Table 1.

UltraScale PA = 0sst trrr rrrc cccc cccc cmmm mmmm
UltraScale+ PA = 00ss 0ttt rrrr rrcc cccc cccc mmmm mmmm

The Detection Report LA includes both the SLR and LFA address. The LA is formatted to match the LFA error injection command format without the Word and Bit fields and with the most significant nibble zeroed out. For more information, see “Error Injection Using LFA” in mji1696498882949.html#mji1696498882949__table_csk_1wz_qyb.

UltraScale = 0000 0000 0ssL LLLL LLLL LLLL LLLL
UltraScale+ = 0000 0000 0000 ssLL LLLL LLLL LLLL LLLL

For the case of correctable errors, the controller lists out all the word and bits (up to four for a single frame) of all the errors it detected.