After attempting correction of an error, the solution classifies the error. The classification result depends on the correction mode, error type, error location, and selected classification mode. The following table provides error classification latency for a configuration frame upset, assuming no throttling on the Monitor Interface.
Device Family | Errors in Frame (Correctability) | Classification Mode | Error Classification Latency at ICAP_FMax (µs) |
---|---|---|---|
UltraScale | Correctable | Enabled | 185 1 |
Uncorrectable | Any | 5 1 | |
UltraScale+ Monolithic | Correctable | Enabled | 154 2 |
Uncorrectable | Any | 5 2 | |
UltraScale+ SSI | Correctable | Enabled | 247 3 |
Uncorrectable | Any | 30 3 | |
|
The error classification latency at the actual frequency of operation can be estimated using data from the previous table and the following equation.
Figure 1. Classification Latency