The following table shows the relationship between the fields in the AMD Vivado™ IDE and the user parameters (which can be viewed in the Tcl Console).
Vivado IDE Parameter | User Parameter | Default Value | Allowable Value |
---|---|---|---|
DSI_LANES | DSI Lanes | 1 to 4 | Maximum of four lanes |
DSI_DATATYPE | DSI Data type | RGB888 |
RGB666 (Loosely, Packed), RGB565, RGB888, Compressed Pixel stream. (Only formats listed in sec 10.2.1 of DSI Specification are supported.) |
DSI_CRC_GEN | CRC Generation logic | 1 |
0: No CRC calculated for long packets, fixed to 0x0000 1: CRC calculated for long packets |
C_DSI_XMIT_INITIAL_DESKEW |
Enable Initial Deskew Transmission |
0 |
0: No initial skew calibration packets sent. 1: the core generates initial skew calibration packets. |
C_INCLUDE_DCS_CMD_MODE | DCS Command Mode, | 0 |
0: The subsystem does not support command only mode and long command packets. 1: Supports long and short commands in command mode. |
DSI_PIXELS | Input Pixels per beat | 1 |
Pixels per beat received on input stream interface Single pixel per beat Dual pixels per beat Quad pixels per beat |
DHY_LINERATE | Line Rate (Mbps) | 800 |
Versal Adaptive SoCs: 260–2500 Mbps UltraScale+ /7 series: 80–2500 Mbps |
DPHY_LPX_PERIOD | LPX Period (ns) | 50 | 50–100 (ns) |
C_EN_CTS_TX | Guarantees the rising edge clock alignment to first payload data bit | False |
True: Guarantees the rising edge clock alignment to first payload data bit. False: Do not guarantee the rising edge clock alignment to first payload data bit. Note: Applicable only for Versal
devices.
|
DPHY_EN_REGIF | Enable AXI4-Lite Register I/F | 0 |
0: Disable register interface for DPHY 1: Enable register interface for DPHY |
SupportLevel | Shared Logic | 0 | |
HP_IO_BANK_SELECTION | HP IO Bank Selection | Value based on part selected. | |
CLK_LANE_IO_LOC | Clock Lane | Value based on part selected. | |
DATA_LANE0_IO_LOC | Data Lane0 | Value based on part selected. | |
DATA_LANE1_IO_LOC | Data Lane1 | Value based on part selected. | |
DATA_LANE2_IO_LOC | Data Lane2 | Value based on part selected. | |
DATA_LANE3_IO_LOC | Data Lane 3 | Value based on part selected. | |
C_EN_HS_OBUFTDS | Infer OBUFTDS for 7Series HS outputs | 0 | Enable OBUFTDS for 7 series devices |