Jumpers

VPK120 Evaluation Board User Guide (UG1568)

Document ID
UG1568
Release Date
2022-08-24
Revision
1.1 English

The following table lists the default jumper settings.

Table 1. Default Jumper Settings
Callout Number Ref. Des. Function Default Schematic Page
1 J12 SYSMON VREFP SEL

1-2: External VREF

2-3: Disable external VREF

1-2 12
2 J26 POR_B supervisor SENSE input

1-2: VCCO_MIO ramp-up sense (1.8V)

2-3: VCCAUX_PMC ramp-up sense (1.5V)

1-2 15
3 J326 POR_B enable header

1-2: SYSCTLR can drive POR_B

3-4: PC4 can drive POR_B

5-6: FTDI can drive POR_B

Open: POR_B source not connected

1-2, 3-4 jumpered

5-6 open

15
4 J34 VCC fuse enable

1-2: Fuse enabled

2-3: Fuse disabled

2-3 16
5 J37 JTAG source enable

1-2: JTAG sources disabled

2-3: JTAG sources enabled

2-3 24
6 J300 USB shield GND

1-2: USB connector DC grounded

2-3: USB connector no DC grounded

1-2 41
7 J60 PCIe PRSNT_B WIDTH SEL

1-2: x1

3-4: x4

5-6: x8

7-8: x16

1-2, 3-4, 5-6, 7-8 44
8 J301 SD REF

1-2: 3.3V REF

2-3: GND REF

1-2 39
9 J203 SYSCTLR POR_B supervisor enable

1-2: SYSCTLR POR_B supervisor enabled

Open: SYSCTLR POR_B supervisor disabled

1-2 75
10 J11 SYSMON header

Open: header for test access

Open 12
11 J347 Fan type

1-2: System controller PWM

2-3: Versal ACAP MIO PWM

2-3 49
11 J348 TACH type

1-2: System controller TACH

2-3: Versal ACAP MIO TACH

2-3 49
12 J345 LPDMGTYAVTT enable select

Installed: Versal ACAP control

Not installed: enabled by UTIL_5V0_PGOOD

Open 68