Clocking Recommendations for Platforms and Dynamic Function eXchange - 2021.1 English

Versal ACAP Hardware, IP, and Platform Development Methodology Guide (UG1387)

Document ID
UG1387
Release Date
2021-07-26
Version
2021.1 English

This section covers the clocking guidelines for Dynamic Function eXchange (DFX) designs. In general, clocks in a DFX design are categorized as internal clocks and boundary clocks:

Reconfigurable module internal clocks
Clocks with driver and loads inside the reconfigurable module (RM).
Boundary clocks
Clocks with nets crossing the cell boundary of the reconfigurable module as follows:
  • Driver in the static region and loads in the RM
  • Driver in the RM and loads in the static region
  • Driver in the static region and loads distributed between RM and static region
  • Driver in the RM region and loads distributed between RM and static region

The following figure shows an example of the different boundary clocks.

Figure 1. DFX Clock Tile Sharing