X-Ref Target - Figure 3-26 |
•Guard traces of 18 mil width must be stitched every 4 mm width of 8 mil drilled vias through the PCB.
•Guard traces must be 15 mils away from signal traces.
•Each individual ground stitch via can have a true tolerance of ±1 mm from nominal.
•Trace width = 5.8 mils.