3. Power Supply Voltage Levels and VCCINT_IO Connection - 3. Power Supply Voltage Levels and VCCINT_IO Connection - UG583

UltraScale Architecture PCB Design User Guide (UG583)

Document_ID
UG583
Release_Date
2025-12-23
Revision
1.29 English

For UltraScale and UltraScale+ FPGAs in the -3, -2, or -1 speed grades, it is required to connect VCCINT_IO to VCCINT and VCCBRAM. However, for UltraScale+ -2L and -1L FPGAs, it is required to connect VCCINT_IO to VCCBRAM.

To support this requirement, the system shown in the following table is recommended with the following figure. The VCCBRAM plane must be sized appropriately to support the additional load for VCCINT_IO when using -2L or -1L devices.

It is possible to connect VCCINT, VCCINT_IO, and VCCBRAM together when using -2 or -1 devices because the respective voltages are the same. It is also possible to connect VCCINT, VCCINT_IO, and VCCBRAM together when using -2L or -1L devices if VCCINT is always operated at 0.85V.

Table 1. VCCINT/VCCINT_IO/VCCBRAM Connection Matrix
  -3, -2, -1 -2L, -1L
VCCINT_IO connection VCCINT/VCCBRAM VCCBRAM
VCCINT sense line connection Averaged with VCCINT_IO Single connection to VCCINT
VCCBRAM sense line connection Single connection to VCCBRAM Averaged with VCCINT_IO
R1 0Ω 0603 0Ω 0603
R2 0Ω 0603 Do not populate
R3 10Ω 0603 10Ω 0603
R4 10Ω 0603 Do not populate
R5 Do not populate 10Ω 0603
R6 10Ω 0603 10Ω 0603
Figure 1. Reference Layout to Support VCCINT/VCCINT_IO/VCCBRAM Connection Matrix