AC Voltage Overshoot 1 | % of UI 2 at –40°C to 100°C 3 | AC Voltage Undershoot 1 | % of UI 2 at –40°C to 100°C 3 |
---|---|---|---|
VCCO + 0.30 | 100% | –0.30 | 100% |
VCCO + 0.35 | 100% | –0.35 | 90% |
VCCO + 0.40 | 100% | –0.40 | 78% |
VCCO + 0.45 | 100% | –0.45 | 40% |
VCCO + 0.50 | 100% | –0.50 | 24% |
VCCO + 0.55 | 100% | –0.55 | 18.0% |
VCCO + 0.60 | 100% | –0.60 | 13.0% |
VCCO + 0.65 | 100% | –0.65 | 10.8% |
VCCO + 0.70 | 92% | –0.70 | 9.0% |
VCCO + 0.75 | 92% | –0.75 | 7.0% |
VCCO + 0.80 | 92% | –0.80 | 6.0% |
VCCO + 0.85 | 92% | –0.85 | 5.0% |
VCCO + 0.90 | 92% | –0.90 | 4.0% |
VCCO + 0.95 | 92% | –0.95 | 2.5% |
|
AC Voltage Overshoot 1 | % of UI 2 at –40°C to 100°C 3 | AC Voltage Undershoot 1 | % of UI 2 at –40°C to 100°C 3 |
---|---|---|---|
VCCO + 0.30 | 100% | –0.30 | 100% |
VCCO + 0.35 | 100% | –0.35 | 100% |
VCCO + 0.40 | 92% | –0.40 | 92% |
VCCO + 0.45 | 50% | –0.45 | 50% |
VCCO + 0.50 | 20% | –0.50 | 20% |
VCCO + 0.55 | 10% | –0.55 | 10% |
VCCO + 0.60 | 6% | –0.60 | 6% |
VCCO + 0.65 | 2% | –0.65 | 2% |
VCCO + 0.70 | 2% | –0.70 | 2% |
|
AC Voltage Overshoot 1 | % of UI 2 at –40°C to 100°C 3 | AC Voltage Undershoot 1 | % of UI 2 at –40°C to 100°C 3 |
---|---|---|---|
VCCO_PSIO + 0.30 | 100% | –0.30 | 100% |
VCCO_PSIO + 0.35 | 100% | –0.35 | 75% |
VCCO_PSIO + 0.40 | 100% | –0.40 | 45% |
VCCO_PSIO + 0.45 | 100% | –0.45 | 40% |
VCCO_PSIO + 0.50 | 75% | –0.50 | 10% |
VCCO_PSIO + 0.55 | 75% | –0.55 | 6% |
VCCO_PSIO + 0.60 | 60% | –0.60 | 2% |
VCCO_PSIO + 0.65 | 30% | –0.65 | 0% |
VCCO_PSIO + 0.70 | 20% | –0.70 | 0% |
VCCO_PSIO + 0.75 | 10% | –0.75 | 0% |
VCCO_PSIO + 0.80 | 10% | –0.80 | 0% |
VCCO_PSIO + 0.85 | 8% | –0.85 | 0% |
VCCO_PSIO + 0.90 | 6% | –0.90 | 0% |
VCCO_PSIO + 0.95 | 6% | –0.95 | 0% |
|