LVDS DC Specifications (LVDS)

Zynq UltraScale+ MPSoC Data Sheet: DC and AC Switching Characteristics (DS925)

Document ID
DS925
Release Date
2024-07-12
Revision
1.27 English

The LVDS standard is available in the HP I/O banks. See the UltraScale Architecture SelectIO Resources User Guide (UG571) for more information.

Table 1. LVDS DC Specifications
Symbol DC Parameter Conditions Min Typ Max Units
VCCO 1 Supply voltage 1.710 1.800 1.890 V
VODIFF 2 Differential output voltage:

(Q – Q), Q = High

(Q – Q), Q = High

RT = 100Ω across Q and Q signals 247 350 454 mV
VOCM 2 Output common-mode voltage RT = 100Ω across Q and Q signals 1.000 1.250 1.425 V
VIDIFF 3 Differential input voltage:

(Q – Q), Q = High

(Q – Q), Q = High

100 350 600 3 mV
VICM_DC 4 Input common-mode voltage (DC coupling) 0.300 1.200 1.425 V
VICM_AC 5 Input common-mode voltage (AC coupling) 0.600 1.100 V
  1. In HP I/O banks, when LVDS is used with input-only functionality, it can be placed in a bank where the VCCO levels are different from the specified level only if internal differential termination is not used. In this scenario, VCCO must be chosen to ensure the input pin voltage levels do not violate the Recommended Operating Condition (Table 1) specification for the VIN I/O pin voltage.
  2. VOCM and VODIFF values are for LVDS_PRE_EMPHASIS = FALSE.
  3. Maximum VIDIFF value is specified for the maximum VICM specification. With a lower VICM, a higher VDIFF is tolerated only when the recommended operating conditions and overshoot/undershoot VIN specifications are maintained.
  4. Input common mode voltage for DC coupled configurations. EQUALIZATION = EQ_NONE (Default).
  5. External input common mode voltage specification for AC coupled configurations. EQUALIZATION = EQ_LEVEL0, EQ_LEVEL1, EQ_LEVEL2, EQ_LEVEL3, EQ_LEVEL4.