Logo Start Y (0x2008) Register - 5.2 English

Video Mixer LogiCORE IP Product Guide (PG243)

Document ID
PG243
Release Date
2024-01-02
Version
5.2 English

The Logo Start Y register marks the y position (rows) of the top left corner of the logo relative to the mixer output frame dimensions. (0,0) puts the logo in the top left corner of the output frame. To avoid processing errors, you should restrict values written to start y such that the entire logo is contained within the frame.