[Figure 1, callout 13]
The VMK180 board hosts dual-port zSFP/zSFP+ J287, which accepts zSFP or zSFP+ modules. The following figure shows the zSFP/zSFP+ module connector circuitry typical of the two implementations.
The following table lists the zSFP+ module control and status connections.
zSFP Control/Status Signal | Board Connection | zSFP Module | |
---|---|---|---|
SFP0_TX_FAULT | Test point J276 | High = Fault | zSFP0 J287 lower |
Low = Normal operation | |||
SFP0_TX_DISABLE | Jumper J35 | Off = SFP disabled | |
On = SFP enabled | |||
SFP0_MOD_DETECT | Test point J31 | High = Module not present | |
Low = Module present | |||
SFP0_RS0 1 | PU R1420/PD R1426 | PU R25 = Full RX bandwidth | |
PD R30 = Reduced RX bandwidth | |||
SFP0_RS1 1 | PU R1421/PD R1427 | PU R227 = Full RX bandwidth | |
PD R142 = Reduced RX bandwidth | |||
SFP0_LOS | Test point J33 | High = Loss of receiver signal | |
Low = Normal operation | |||
SFP1_TX_FAULT | Test point J30 | High = Fault | zSFP1 J287 upper |
Low = Normal operation | |||
SFP1_TX_DISABLE | Jumper J32 | Off = SFP disabled | |
On = SFP enabled | |||
SFP1_MOD_DETECT | Test point J277 | High = Module not present | |
Low = Module present | |||
SFP1_RS0 1 | PU R1428/PD R1431 | PU R182 = Full RX bandwidth | |
PD R190 = Reduced RX bandwidth | |||
SFP1_RS1 1 | PU R1429/PD R1432 | PU R185 = Full RX bandwidth | |
PD R202 = Reduced RX bandwidth | |||
SFP1_LOS | Test point J278 | High = Loss of receiver signal | |
Low = Normal operation | |||
|
For additional information about the enhanced SFP+ module, see the SFF-8431 specification at the SNIA website.
The zSFP connector I2C interfaces are connected to the I2C bus via the TCA9548 I2C multiplexer U214 (see PMC MIO[46:47] I2C0 Bus and PMC MIO[44:45] I2C1 Bus for more details).
The detailed Versal adaptive SoC connections for the feature described in this section are documented in the VMK180 board XDC file, referenced in Xilinx Design Constraints.