The Versal XCVM1802 device boot process is described in the “Platform Boot, Control, and Status” section of the Versal Adaptive SoC Technical Reference Manual (AM011). The VMK180 board supports a subset of the modes documented in the technical reference manual via onboard and mezzanine card boot options. The mode DIP switch SW1 configuration option settings are listed in the following table.

Table 1. Mode Switch SW1 Configuration Option Settings
Boot Mode Mode Pins [3:0] 2 Mode SW1 [4:1] 2 Comments
JTAG 0000 1, 3 ON, ON, ON, ON Supported with or without boot module attached
QSPI32 0010 ON, ON, OFF, ON Supported only with boot module X-EBM-01 attached

Supports x1, x2, x4, and dual-parallel x8

SD1_3.0 1110 OFF, OFF, OFF, ON Supported with or without boot module attached
  1. Default switch setting.
  2. Mode DIP SW1 poles [4:1] correspond to U1 XCVM1802 MODE[3:0].