Get the current board object
Syntax
current_board [‑quiet] [‑verbose]
Returns
Current board object.
Usage
Name | Description |
---|---|
[-quiet]
|
Ignore command errors |
[-verbose]
|
Suspend message limits during command execution |
Description
Returns the board in use in the current project.
The board file, board.xml located in the data/boards folder of the Vivado® Design Suite installation area, stores information regarding board attributes. The board provides a representation of the overall system that the Xilinx® device is a part of, and can help define key aspects of the design, such as clock constraints, I/O port assignments, and supported interfaces. You can create custom boards by defining a custom Board Interface file, as described in the Vivado Design Suite User Guide: System-Level Design Entry (UG895).
- When the project is created by selecting Boards from the Default Part dialog box.
- By setting the BOARD_PART property on the current project as shown in the example.
- By selecting the Project Device in the Settings dialog box in an open project in the Vivado IDE.
set_property
command, the target part is also changed to match the part required by the specified BOARD property.The current_board
command returns the Vendor:Board_Name:File_Version
attributes of the current board, as defined in the BOARD_PART property. The command returns nothing when the project targets a Xilinx FPGA instead of a TRD and board, or when the BOARD_PART property has not been defined. The command returns an error if it fails.
Arguments
-quiet
- (Optional) Execute the command quietly, returning no messages from the command. The command also returns TCL_OK regardless of any errors encountered during execution.
-verbose
- (Optional) Temporarily override any message limits and return all messages from this command.
set_msg_config
command.Example
set_property BOARD_PART xilinx.com:kc705:1.0 [current_project]
current_board
xilinx.com:kintex7:kc705:1.0
set_property BOARD_PART xilinx.com:ac701:1.0 [current_project]
WARNING: [Project 1-153] The current project part 'xc7k325tffg900-2' does
not match with the 'XILINX.COM:AC701:1.0' board part settings. The project
part will be reset to 'XILINX.COM:AC701:1.0' board part.
report_property
command to check the BOARD_PART and PART property on the current_project