AXI Clock Converter Resource Utilization - 2.1 English

AXI Interconnect LogiCORE IP Product Guide (PG059)

Document ID
PG059
Release Date
2022-05-17
Version
2.1 English

Common Configuration:

ID Width: 2 (AXI4 and AXI3 only)

Address Width: 22

User Width: 0

Target device: xc7vx485t

Table 2-19:      AXI Clock Converter Resource Utilization

Protocol

Clock
Conversion

Data
Width

Read/Write

Read-Only

Write-Only

LUTs

FFs

LUTs

FFs

LUTs

FFs

AXI4,
AXI3

Sync
(Any Ratio)

32

110

300

50

140

60

160

64

180

430

80

210

100

230

128

320

700

150

330

170

370

256

590

1250

280

590

310

660

512

1130

2340

530

1100

600

1240

1024

2220

4510

1040

2130

1180

2390

Async

32

300

860

130

380

170

480

64

350

990

150

440

190

550

128

440

1260

200

570

240

700

256

620

1810

280

820

340

980

512

980

2900

450

1340

530

1560

1024

1710

5070

790

2360

910

2710

AXI4-Lite

Sync
(Any Ratio)

32

40

160

10

80

20

80

64

40

230

10

110

20

120

Async

32

270

730

110

310

150

420

64

320

870

140

380

180

490