Clock Conversion Options - 2.1 English

AXI Interconnect LogiCORE IP Product Guide (PG059)

Document ID
PG059
Release Date
2022-05-17
Version
2.1 English

SI to MI Clock Ratio
Available only when "Is ACLK Asynchronous" is 0.

°Description: Ratio of SI-side clock frequency to MI.

°Format/Range: String (“16:1”…”2:1”, “1:2”…"1:16”)

°Default Value: 1:2

Is ACLK Asynchronous

°Description: Enable asynchronous conversion. You can override automatic value from 0 to 1 to force asynchronous conversion.

°Format/Range: Integer (0, 1)

°Default Value: 1