The following is an example of a parameter mismatch on the FREQ_HZ
property of a clock pin. In this example, the frequency does not match between the S01_AXI
port and the S_AXI
interface of the AXI Interconnect. This error is revealed when the design is validated.
Figure 1. FREQ_HZ Property Mismatch Between Port and Interface Pin
- The
S01_AXI
port has a frequency of 200 MHz as can be seen in the properties window. - The
S01_AXI
interface of the AXI Interconnect is set to a frequency of 100 MHz.
You can fix this error by changing the frequency in the property, or by double-clicking the S01_AXI
port and correcting the frequency in the Frequency field of the customization dialog box.
Figure 2. Change Frequency Port in Properties Window
After you change the frequency, re-validate the design to ensure there are no errors.