The following table shows the relationship between the fields in the Vivado IDE and the User Parameters (which can be viewed in the tool command language (Tcl) Console).
Vivado IDE Parameters | Parameter Name | Default Value | Allowed Value |
---|---|---|---|
I2S Receiver | |||
Audio Channels | C_NUM_CHANNELS | 2 | 2, 4, 6, 8 |
I2S Data width | C_DWIDTH | 24 | 16, 24 |
32bit LRCLK | C_32BIT_LR | 0 | 0,1 |
FIFO Depth | C_DEPTH | 128 | 64, 128, 256, 512, 1024 |
I2S Transmitter | |||
Audio Channels | C_NUM_CHANNELS | 2 | 2, 4, 6, 8 |
I2S Data width | C_DWIDTH | 24 | 16, 24 |
32bit LRCLK | C_32BIT_LR | 0 | 0,1 |
FIFO Depth | C_DEPTH | 128 | 64, 128, 256, 512, 1024 |
Enable FIFO Count | C_ENABLE_FIFO_COUNT | False | True, False |