Interrupt Status Register 3 (0x24) - 1.1 English

Soft ECC Proxy LogiCORE IP Product Guide (PG337)

Document ID
PG337
Release Date
2023-11-01
Version
1.1 English
Interrupt Status Register 3 gives the status of double-bit errors occurring on byte N.
Table 1. Interrupt Status Register 3 (0x24)
Bit Name Default Value Access Type Description
N DBE_BYTE_N 0 RO

Double-bit error on byte N. Gives the status of double-bit errors occurring on data bytes 32 to 63.

For example:

Bit 0 corresponds to data byte 32. Bit 1 corresponds to data byte 33.

If bit 0 is High, a double-bit error has occurred on data byte 32.