The parameters in this section provide the necessary values for calculating timing budgets for clock transmitter and receiver data-valid windows.
Symbol | Description | Device | Package | Value | Units |
---|---|---|---|---|---|
PKGSKEW | Package Skew 1, 2 | XCAU7P | FCVA289 | 43 | ps |
SBVC484 | 86 | ps | |||
XCAU10P | UBVA368 | 59 | ps | ||
SBVB484 | 87 | ps | |||
FFVB676 | 81 | ps | |||
XCAU15P | UBVA368 | 59 | ps | ||
SBVB484 | 87 | ps | |||
FFVB676 | 81 | ps | |||
XCAU20P | FFVB676 | 69 | ps | ||
SFVB784 | 75 | ps | |||
XCAU25P | FFVB676 | 69 | ps | ||
SFVB784 | 75 | ps | |||
XAAU7P | FCVA289 | 43 | ps | ||
SBVC484 | 86 | ps | |||
XAAU10P | SBVB484 | 87 | ps | ||
FFVB676 | 81 | ps | |||
XAAU15P | SBVB484 | 87 | ps | ||
FFVB676 | 81 | ps | |||
|