Clocking - 2.2 English

Semi-Ternary CAM Search LogiCORE IP Product Guide (PG319)

Document ID
PG319
Release Date
2021-07-27
Version
2.2 English
Table 1. Clocks
Clock Description
s_axi_aclk The AXI clock is used for table management. The AXI management interface has a completely asynchronous relationship with the lookup interface.
key_clk AXI4-Stream clock for Lookup Request/Response interfaces.
ram_clk The ram_clk is optional. It provides an option to clock the internal RAM and match logic on a separate high frequency clock. In most cases this saves logic and memory resources.
Guideline:
  • key_clk <= 300 MHz, use ram_clk up to 600 MHz
  • key_clk > 300 MHz, ram_clk is not used