Revision History

Versal Prime Series Production Errata (EN314)

Document ID
EN314
Release Date
2024-11-25
Revision
1.6 English

The following table shows the revision history for this document.

Section Revision Summary
11/25/2024 Version 1.6
Devices Added XQVM1102 device.
2/05/2024 Version 1.5
Devices, In RP Mode, ME/BME Bit Does Not Gate Requests, CPM5 CML HA WR_BUFFER RAM Is 96 Deep Instead Of 128, GTM TX CDM ESD Tolerance Is Lower Than The Production Target Added XCVM2302, XCVM2502, and XCVM2902 devices and associated issues.
Primary Boot Is Not Supported With eMMC Devices That Require CMD6 Busy Time Greater Than 1 ms Added PMC primary boot eMMC issue.
6/7/2023 Version 1.4
Devices Added XQVM1502 device.
1/26/2023 Version 1.3
Devices Added XQVM1402 and XCVM1502 devices.
Errata Summary Updated Table 1.
Readback Capture Is Not Supported Removed issue: Not a deviation from the production specification.
Control IMUX Registers Are Not Supported Removed issue: Not a deviation from the production specification.
In RC Mode With SMMU Enabled, CCI Transaction Ordering Is Not Followed Between Different Shareability Domain Memories That Have Same AXI ID New errata issue.
11/09/2022 Version 1.2
Devices Added XQVM1802, XCVM1402, and XCVM1302 devices.
IPOR Issued After An SRST Causes A Boot Failure New errata issue.
11/12/2021 Version 1.1
HDIO/MIO: When An Output Is Powered At 3.3V Or 2.5V, A Race Condition Can Exist Between Data And Tristate New errata issue.
4/14/2021 Version 1.0
Initial release. N/A