The following tables provide the required airflow
rate and airflow speed to X3522 NICs under
various operating conditions for 35W total card power. This is indicative of
requirements when using bundle 1.26.126.3538 for the X3522 low latency network
adapter
.
Inlet Temperature vs Airflow Requirement of PCIe Card Slot (56.51 mm x 20.33 mm) at Sea Level for 35W Total Card Power | ||||||
---|---|---|---|---|---|---|
Inlet Temperature to the Card (°C) | With SFP28 (75°C) | Without SFP28 1 | ||||
CFM | LFM | Static Pressure | CFM | LFM | Static Pressure | |
25 | 1.4 | 110 | 0.08 | 1.4 | 120 | 0.09 |
30 | 1.6 | 130 | 0.10 | 1.7 | 140 | 0.11 |
35 | 2.0 | 160 | 0.12 | 2.1 | 170 | 0.13 |
40 | 2.5 | 210 | 0.17 | 2.6 | 220 | 0.18 |
45 | 3.3 | 270 | 0.24 | 3.5 | 290 | 0.26 |
50 | 4.6 | 380 | 0.38 | 4.9 | 400 | 0.41 |
55 | 7.3 | 600 | 0.74 | 7.7 | 630 | 0.80 |
|
Inlet Temperature vs Airflow Requirement of PCIe Card Slot (56.51 mm x 20.33 mm) at 1200m Above Sea Level for 35W Total Card Power | ||||||
---|---|---|---|---|---|---|
Inlet Temperature to the Card (°C) | With SFP28 (75°C) | Without SFP28 1 | ||||
CFM | LFM | Static Pressure | CFM | LFM | Static Pressure | |
25 | 1.4 | 120 | 0.09 | 1.5 | 130 | 0.09 |
30 | 1.7 | 140 | 0.11 | 1.8 | 150 | 0.12 |
35 | 2.1 | 180 | 0.14 | 2.2 | 190 | 0.15 |
40 | 2.7 | 220 | 0.18 | 2.8 | 230 | 0.20 |
45 | 3.5 | 290 | 0.26 | 3.7 | 310 | 0.28 |
50 | 5.0 | 410 | 0.42 | 5.3 | 430 | 0.46 |
55 | 7.9 | 640 | 0.84 | 8.3 | 680 | 0.90 |
|
Inlet Temperature vs Airflow Requirement of PCIe Card Slot (66.87 mm x 13.18 mm) at Sea Level for 35W Total Card Power | ||||||
---|---|---|---|---|---|---|
Inlet Temperature to the Card (°C) | With SFP28 (75°C) | Without SFP28 1 | ||||
CFM | LFM | Static Pressure | CFM | LFM | Static Pressure | |
25 | 0.7 | 70 | 0.04 | 0.8 | 80 | 0.04 |
30 | 0.8 | 80 | 0.04 | 0.9 | 90 | 0.04 |
35 | 0.9 | 100 | 0.05 | 1.0 | 110 | 0.05 |
40 | 1.0 | 110 | 0.07 | 1.1 | 130 | 0.06 |
45 | 1.2 | 130 | 0.09 | 1.4 | 150 | 0.08 |
50 | 1.5 | 160 | 0.12 | 1.6 | 180 | 0.10 |
55 | 1.6 | 180 | 0.14 | 1.8 | 190 | 0.11 |
60 | 2.1 | 220 | 0.20 | 2.2 | 240 | 0.16 |
|
Inlet Temperature vs Airflow Requirement of PCIe Card Slot (66.87 mm x 13.18 mm) at 1200m Above Sea Level for 35W Total Card Power | ||||||
---|---|---|---|---|---|---|
Inlet Temperature to the Card (°C) | With SFP28 (75°C) | Without SFP28 1 | ||||
CFM | LFM | Static Pressure | CFM | LFM | Static Pressure | |
25 | 0.7 | 80 | 0.04 | 0.8 | 90 | 0.04 |
30 | 0.8 | 90 | 0.05 | 0.9 | 100 | 0.05 |
35 | 0.9 | 100 | 0.06 | 1.1 | 120 | 0.06 |
40 | 1.1 | 120 | 0.08 | 1.2 | 130 | 0.07 |
45 | 1.3 | 140 | 0.10 | 1.5 | 160 | 0.09 |
50 | 1.6 | 180 | 0.13 | 1.8 | 190 | 0.11 |
55 | 1.8 | 190 | 0.15 | 1.9 | 210 | 0.13 |
60 | 2.2 | 240 | 0.22 | 2.4 | 260 | 0.18 |
|
The following tables provide the required airflow
rate and airflow speed to X3522 NICs under
various operating conditions for 70W total card power. This is indicative of
requirements for the
X3522PV
adaptable accelerator card.
Inlet Temperature vs Airflow Requirement of PCIe Card Slot (56.51 mm x 20.33 mm) at Sea Level for 70W Total Card Power | ||||||
---|---|---|---|---|---|---|
Inlet Temperature to the Card (°C) | With SFP28 (75°C) | Without SFP28 1 | ||||
CFM | LFM | Static Pressure | CFM | LFM | Static Pressure | |
25 | 3.6 | 300 | 0.27 | 3.8 | 310 | 0.29 |
30 | 4.3 | 350 | 0.34 | 4.5 | 370 | 0.37 |
35 | 5.2 | 430 | 0.45 | 5.5 | 450 | 0.49 |
40 | 6.6 | 540 | 0.64 | 6.9 | 570 | 0.68 |
45 | 8.7 | 710 | 0.97 | 9.1 | 740 | 1.04 |
50 | 12.3 | 1000 | 1.69 | 12.8 | 1040 | 1.81 |
55 | 19.5 | 1580 | 3.67 | 20.2 | 1640 | 3.92 |
|
Inlet Temperature vs Airflow Requirement of PCIe Card Slot (56.51 mm x 20.33 mm) at 1200m Above Sea Level for 70W Total Card Power | ||||||
---|---|---|---|---|---|---|
Inlet Temperature to the Card (°C) | With SFP28 (75°C) | Without SFP28 1 | ||||
CFM | LFM | Static Pressure | CFM | LFM | Static Pressure | |
25 | 3.9 | 320 | 0.30 | 4.1 | 330 | 0.32 |
30 | 4.6 | 380 | 0.38 | 4.9 | 400 | 0.41 |
35 | 5.6 | 460 | 0.50 | 5.9 | 480 | 0.54 |
40 | 7.1 | 580 | 0.71 | 7.5 | 610 | 0.76 |
45 | 9.4 | 760 | 1.09 | 9.8 | 800 | 1.17 |
50 | 13.3 | 1080 | 1.91 | 13.8 | 1120 | 2.05 |
55 | 21.1 | 1710 | 4.20 | 21.8 | 1770 | 4.48 |
|
Inlet Temperature vs Airflow Requirement of PCIe Card Slot (66.87 mm x 13.18 mm) at Sea Level for 70W Total Card Power | ||||||
---|---|---|---|---|---|---|
Inlet Temperature to the Card (°C) | With SFP28 (75°C) | Without SFP28 1 | ||||
CFM | LFM | Static Pressure | CFM | LFM | Static Pressure | |
25 | 2.6 | 280 | 0.29 | 2.8 | 300 | 0.22 |
30 | 3.0 | 330 | 0.37 | 3.2 | 340 | 0.27 |
35 | 3.5 | 380 | 0.47 | 3.7 | 390 | 0.34 |
40 | 4.2 | 440 | 0.62 | 4.3 | 450 | 0.43 |
45 | 5.0 | 530 | 0.85 | 5.0 | 540 | 0.57 |
50 | 6.1 | 640 | 1.22 | 6.1 | 640 | 0.78 |
55 | 6.6 | 700 | 1.42 | 6.6 | 700 | 0.89 |
60 | 8.3 | 880 | 2.19 | 8.2 | 870 | 1.31 |
|
Inlet Temperature vs Airflow Requirement of PCIe Card Slot (66.87 mm x 13.18 mm) at 1200m Above Sea Level for 70W Total Card Power | ||||||
---|---|---|---|---|---|---|
Inlet Temperature to the Card (°C) | With SFP28 (75°C) | Without SFP28 1 | ||||
CFM | LFM | Static Pressure | CFM | LFM | Static Pressure | |
25 | 2.8 | 300 | 0.33 | 3.0 | 320 | 0.25 |
30 | 3.3 | 350 | 0.41 | 3.4 | 360 | 0.30 |
35 | 3.8 | 400 | 0.53 | 3.9 | 420 | 0.38 |
40 | 4.5 | 480 | 0.71 | 4.6 | 490 | 0.49 |
45 | 5.3 | 570 | 0.97 | 5.4 | 580 | 0.64 |
50 | 6.5 | 690 | 1.40 | 6.5 | 690 | 0.88 |
55 | 7.1 | 760 | 1.64 | 7.1 | 750 | 1.02 |
60 | 9.0 | 960 | 2.53 | 8.8 | 940 | 1.50 |
|