If the design is using the features highlighted above, it is highly recommended to update the design using the following Vivado releases or newer versions.
- For GTYP ES1 or GTY, the fixes are implemented in 2022.2.
- For GTM ES1, the fixes are implemented in 2023.1.
- GTYP/GTM Production devices are not affected by this issue.
The solutions include:
- GT Wizard update
- IBERT tools and PLM update
- Lower NPI clock Fmax specification for devices/temperature grades:
- XCVC1502, XCVC1702, XQVC1702, XQVC1902, XCVM1302, XCVM1402, XQVM1402, XCVM1502, XQVM1502, and XQVM1802 devices in the -1L (VCCINT=0.70V) speed grade
- XCVC1502, XCVC1702, XCVM1302, XCVM1402, and XCVM1502 devices in -2LLI (VCCINT=0.70V) speed grade
For a complete list of Versal GTY/GTYP/GTM release notes and known issues, see:
75716 - Versal Adaptive SoC GTY/GTYP Transceivers Wizard and IBERT - Master Release Notes and Known Issues
000034042 - Versal Adaptive SoC GTM Transceivers Wizard and IBERT - Master Release Notes and Known Issues