AC 電圧オーバーシュート 1 | -40°C ~ 100°C の UI 2 (%) | AC 電圧アンダーシュート 1 | -40°C ~ 100°C の UI 2 (%) |
---|---|---|---|
VCCO + 0.30 | 100% | -0.30 | 100% |
VCCO + 0.35 | 100% | -0.35 | 90% |
VCCO + 0.40 | 100% | -0.40 | 78% |
VCCO + 0.45 | 100% | -0.45 | 40% |
VCCO + 0.50 | 100% | -0.50 | 24% |
VCCO + 0.55 | 100% | -0.55 | 18.0% |
VCCO + 0.60 | 100% | -0.60 | 13.0% |
VCCO + 0.65 | 100% | -0.65 | 10.8% |
VCCO + 0.70 | 92% | -0.70 | 9.0% |
VCCO + 0.75 | 92% | -0.75 | 7.0% |
VCCO + 0.80 | 92% | -0.80 | 6.0% |
VCCO + 0.85 | 92% | -0.85 | 5.0% |
VCCO + 0.90 | 92% | -0.90 | 4.0% |
VCCO + 0.95 | 92% | -0.95 | 2.5% |
|
AC 電圧オーバーシュート 1 | -40°C ~ 100°C の UI 2 (%) | AC 電圧アンダーシュート 1 | -40°C ~ 100°C の UI 2 (%) |
---|---|---|---|
VCCO + 0.30 | 100% | -0.30 | 100% |
VCCO + 0.35 | 100% | -0.35 | 100% |
VCCO + 0.40 | 92% | -0.40 | 92% |
VCCO + 0.45 | 50% | -0.45 | 50% |
VCCO + 0.50 | 20% | -0.50 | 20% |
VCCO + 0.55 | 10% | -0.55 | 10% |
VCCO + 0.60 | 6% | -0.60 | 6% |
VCCO + 0.65 | 2% | -0.65 | 2% |
VCCO + 0.70 | 2% | -0.70 | 2% |
|
AC 電圧オーバーシュート 1 | -40°C ~ 100°C 3 の UI 2 (%) | AC 電圧アンダーシュート 1 | -40°C ~ 100°C 3 の UI 2 (%) |
---|---|---|---|
VCCO_PSIO + 0.30 | 100% | -0.30 | 100% |
VCCO_PSIO + 0.35 | 100% | -0.35 | 75% |
VCCO_PSIO + 0.40 | 100% | -0.40 | 45% |
VCCO_PSIO + 0.45 | 100% | -0.45 | 40% |
VCCO_PSIO + 0.50 | 75% | -0.50 | 10% |
VCCO_PSIO + 0.55 | 75% | -0.55 | 6% |
VCCO_PSIO + 0.60 | 60% | -0.60 | 2% |
VCCO_PSIO + 0.65 | 30% | -0.65 | 0% |
VCCO_PSIO + 0.70 | 20% | -0.70 | 0% |
VCCO_PSIO + 0.75 | 10% | -0.75 | 0% |
VCCO_PSIO + 0.80 | 10% | -0.80 | 0% |
VCCO_PSIO + 0.85 | 8% | -0.85 | 0% |
VCCO_PSIO + 0.90 | 6% | -0.90 | 0% |
VCCO_PSIO + 0.95 | 6% | -0.95 | 0% |
|