APIs | Inputs | Outputs |
---|---|---|
write_data
Initiate a WRITE transaction (transfer size ≤ 16 bytes) on one of the AXI-Master ports. This calls the AXI VIP API. This task returns write response when the write transaction is completed. For example:
|
[1023:0] master_name: R5_API or A72_API. [43:0] start_addr: Write address [4:0] wr_size: Number of bytes to be written. Valid Write Sizes are:
Note: Transfer should not cross the 16-byte
boundary.
Note: start_addr should be 32-bit
aligned.
If start_addr[1:0] = 4'h0 -> wr_size can be 5'h4/5'h8/5'hC/5'h10 = 4'h4 -> wr_size can be 5'h4/5'h8/5'hC = 4'h8 -> wr_size can be 5'h4/5'h8 = 4'hC -> wr_size can be 5'h4 [127:0] w_data: Data to be written |
[1:0] response: The slave write response from the
following: [OKAY, EXOKAY, SLVERR, DECERR] |
read_data
Initiate a READ transaction (transfer size ≤ 16 bytes) on one of the AXI-Master ports. This calls the AXI VIP API. This task returns data and response when the read transaction is completed. For example:
|
[1023:0] master_name: R5_API or A72_API. [43:0] start_addr: Read address [4:0] rd_size: Number of bytes to be read Valid Read Sizes are
Note: Transfer should not cross the 16-byte
boundary.
Note: start_addr should be 32-bit
aligned.
If start_addr[1:0] = 4'h0 -> rd_size can be 5'h4/5'h8/5'hC/5'h10 = 4'h4 -> rd_size can be 5'h4/5'h8/5'hC = 4'h8 -> rd_size can be 5'h4/5'h8 = 4'hC -> rd_size can be 5'h4 |
[127:0] rd_data: Valid Data from the slave [1:0] response: The slave read response from the following: [OKAY, EXOKAY, SLVERR, DECERR] |
write_data_32
Initiate a WRITE transaction of 4 bytes on one of the AXI-Master ports. This calls the AXI VIP API. This task returns write response when the write transaction is completed. For example: |
[1023:0] master_name: R5_API or A72_API. [43:0] start_addr: write address [31:0] w_data: Data to be written Note: start_addr should be 32-bit aligned.
|
[1:0] response: The slave write response from the following: [OKAY, EXOKAY, SLVERR, DECERR] |
write_data_64
Initiate a WRITE transaction of 8 bytes on one of the AXI-Master ports. This calls the AXI VIP API. This task returns write response when the write transaction is completed. For example: |
[1023:0] master_name: R5_API or A72_API. [43:0] start_addr: write address [63:0] w_data: Data to be written Note: start_addr should be 64-bit
aligned.
|
[1:0] response: The slave write response from the
following: [OKAY, EXOKAY, SLVERR, DECERR] |
read_data_32
Initiate a READ transaction of 4 bytes on one of the AXI-Master ports. This calls the AXI VIP API. This task returns data and response when the read transaction is completed. For example: |
[1023:0] master_name: R5_API or A72_API. [43:0] start_addr: Read address Note: start_addr should be 32-bit
aligned.
|
[31:0] rd_data: Valid Data from the slave[1:0]
response: The slave read response from the following: [OKAY, EXOKAY, SLVERR, DECERR] |
read_data_64
Initiate a READ transaction of 8 bytes on one of the AXI-Master ports. This calls the AXI VIP API. This task returns data and response when the read transaction is completed. For example: |
[1023:0] master_name: R5_API or A72_API. [43:0] start_addr: Read address Note: start_addr should be 64-bit
aligned.
|
[63:0] rd_data: Valid Data from the slave[1:0]