Poison Address Register

Memory and Peripheral Protection Unit for PL Isolation in Zynq UltraScale+ Devices (XAPP1353)

Document ID
XAPP1353
Release Date
2022-05-04
Revision
1.1 English

The POISON register is shown in the following table.

Table 1. POISON (XMPU_PL) Register Bit Field Summary
Field Name Bits Type Reset Value Description
PL_SINK_ADDR 31:0 rw 0x00800000

The value is set by user for poison base address, determined by PL Address Mapping. The XMPU replaces the incoming AXI address (39 down to 8) with the PL_SINK_ADDR. Address (7 down to 0) is retained from the originating address for alignment. Downstream, the XMPU_PL_Sink unit responds to the transaction.