Table 4 vvas_xinfer Plug-in Properties

Property Name

Type

Range

Default

Description

config-file

String

N/A

Null

Absolute path, including file name, of the JSON configuration file.

batch-timeout

Integer

0 to UINT_MAX

2000

Timeout in milliseconds to wait for batch size number of frames to arrive before processing a partial batch. A value of 0 indicates no timeout (wait indefinitely until batch size is reached).

enable-profiler

Boolean

true/false

false

Enables or disables the profiler for inference backend runtime.

profiler-file

String

N/A

Null

Specifies the file path to write the profiler output.

profiler-log-interval

Integer

1 to 60

0

Sets the duration (in seconds) for logging profiling details at GST_INFO log level.