Step 2: Running Report Power in Vectorless Mode - Step 2: Running Report Power in Vectorless Mode - 2026.1 English - UG997

Vivado Design Suite Tutorial: Power Analysis and Optimization (UG997)

Document ID
UG997
Release Date
2026-06-23
Version
2026.1 English
  1. In the Flow Navigator, select Open Implemented Design > Report Power to open the Report Power dialog box.

    You can also select Reports > Report Power from the main menu.

  2. In the Report Power dialog box, in the Environment tab, make sure that the Process is set to maximum and click OK.

    The Report Power command creates a power report under the power_1 tab in the Power window.

  3. Note the total power (Total On-Chip Power) in the power report in the Summary page.

    Vectorless analysis is achieved based on default switching activity specification on the primary ports and the design clocks.

    Refer to Vivado Design Suite User Guide: Power Analysis and Optimization (UG907) for more information on vectorless power analysis.