Figure 1. andnli
Description
The IMM field is sign-extended with the immediate value from the preceding imml instructions. The contents of register rAL or rDL are ANDed with the logical complement of the extended IMM field; the result is placed into register rDL.
Pseudocode
(rDL) ← (rAL|rDL) ˄ (sext(IMM))
Registers Altered
- rDL
Latency
- 1 cycle
Note
- Type B logical long instructions with three operands must be preceded by an imml instruction. See the instruction imml for details on using long immediate values.