The required signals used in DDR5 applications are shown in the following table. The signal list might vary slightly depending on the particular DDR5 architecture used.

Table 1. DDR5 Signal Definitions
Signal Description Required PCB Termination
Clock Signals
CK_T/C Address/Command clock None, uses ODT to 40Ω
Command/Address Signals
CA[13:0] Address None, uses ODT to 40Ω
Control Signals
CS_N Chip Select None, uses ODT to 40Ω
LBDQ DQ Loopback (calibration) None, uses ODT to 40Ω
LBDQS DQS Loopback (calibration) None, uses ODT to 40Ω
PAR_A, PAR_B (DIMMs) Command/Address Parity None, uses ODT to 40Ω
Data Signals
DQ[n:0] Data None, uses ODT to 40Ω
DM_N Write Data Mask None, uses ODT to 40Ω
Data Strobe Signals
DQS_T/C[n:0] Differential Data Strobe None, uses ODT to 40Ω
Miscellaneous Signals
ALERT_N (components) CRC Error Flag Open-Drain Output Connect ALERT_N pins as flyby and terminate to VDDQ with a 50Ω resistor
ALERT_N (DIMMs) CRC Error Flag Open-Drain Output None
RESET_n Reset 4.7 kΩ to GND (at end of fly-by when using multiple devices)
DDR5 Device/DIMM Only
CAI Command Address Invert Connect direct to GND
CA_ODT Command/Address ODT When multiple components are used in fly-by routing: Direct to ground for all devices except the last which is tied directly to VDDQ
HSA, HSCL, HSDA (DIMM) Host Sideband Signals Connect as required in system (see JEDEC specification)
MIR (clamshell) CA Mirror

Direct to GND (standard mode)

Direct to VDDQ (mirrored mode)

MIR (non-clamshell) CA Mirror Direct to GND
PCAMP Control and Monitor Port Has Three Possible Functions (see JEDEC specification)
PWR_EN/POWER_GOOD (DIMM) Power Good (Open Drain)/PMIC Enable Connect as required in system (see JEDEC specification)
TEN Connectivity Test Mode Connect direct to GND
VIN_BULK (DIMMs) PMIC Analog power input supply 12V (RDIMM)

5V( UDIMM)

VIN_MGMT (RDIMM) Management Supply Voltage 3.3V (RDIMM)
ZQ Calibration Reference (per device) 240Ω to GND
Adaptive SoC Only

IO_VR_7xx

IO_VR_8xx (if present)

Calibration Reference

240Ω to VCCO_7xx