Field Name Bits Type Reset Value Description
reserved 31 rw 0x0 Reserved. Do not modify.
reg_phy_cmd_latency 30 rw 0x0 If set to 1, command comes to phy_ctrl through a flop.
reg_phy_lpddr 29 rw 0x0

0: LPDDR2, DDR2 or DDR3

1: reserved

reserved 28 rw 0x1 Reserved. Do not modify.
reg_phy_ctrl_slave_delay 27:21 rw 0x0 If reg_phy_rd_dqs_slave_force is 1, replace delay/tap value for address/command timing slave DLL with this value. This is a bit value, the remaining 2 bits are in register 0x65 bits[19:18].
reg_phy_ctrl_slave_force 20 rw 0x0

0: Use reg_phy_ctrl_slave_ratio for address/command timing slave DLL

1: overwrite the delay/tap value for address/command timing slave DLL with the value of the reg_phy_rd_dqs_slave_delay bus.

reg_phy_ctrl_slave_ratio 19:10 rw 0x80 Ratio value for address/command launch timing in phy_ctrl macro. This is the fraction of a clock cycle represented by the shift to be applied to the read DQS in units of 256ths. In other words, the full cycle tap value from the master DLL will be scaled by this number over 256 to get the delay value for the slave delay line.
reg_phy_sel_logic 9 rw 0x0

Selects one of the two read leveling algorithms.'b0: Select algorithm # 1'b1: Select algorithm # 2

Please refer to Read Data Eye Training section in PHY User Guide for details about the Read Leveling algorithms

reserved 8 rw 0x0 Reserved. Do not modify.
reg_phy_invert_clkout 7 rw 0x0

Inverts the polarity of DRAM clock.

0: core clock is passed on to DRAM

1: inverted core clock is passed on to DRAM.

Use this when CLK can arrive at a DRAM device ahead of DQS or coincidence with DQS based on board topology. This effectively delays the CLK to the DRAM device by half -cycle, providing a CLK edge that DQS can align to during leveling.

reserved 6:5 rw 0x0 Reserved. Do not modify.
reserved 4 rw 0x0 Reserved. Do not modify.
reserved 3 rw 0x0 Reserved. Do not modify.
reserved 2 rw 0x0 Reserved. Do not modify.
reg_phy_bl2 1 rw 0x0 Reserved for future Use.