| Field Name | Bits | Type | Reset Value | Description |
|---|---|---|---|---|
| reg_phy_wrlvl_num_of_dq0 | 31:28 | rw | 0x0 |
This register value determines the number of samples used for each ratio increment during Write Leveling. Num_of_iteration = reg_phy_wrlvl_num_of_dq0 + 1 The recommended value for this register is 8. Accuracy is better with higher value, but this will cause leveling to run longer. |
| reg_phy_gatelvl_num_of_dq0 | 27:24 | rw | 0x0 |
This register value determines register determines the number of samples used for each ratio increment during Gate Training. Num_of_iteration = reg_phy_gatelvl_num_of_dq0 + 1 The recommended value for this register is 8. Accuracy is better with higher value, but this will cause leveling to run longer. |
| reserved | 23:20 | ro | 0x0 | Reserved |
| reg_phy_clk_stall_level | 19 | rw | 0x0 | 1: stall clock, for DLL aging control |
| reg_phy_dis_phy_ctrl_rstn | 18 | rw | 0x0 |
Disable the reset from Phy Ctrl macro. 1: PHY Ctrl macro reset port is always HIGH 0: PHY Ctrl macro gets power on reset. |
| reg_phy_rdc_fifo_rst_err_cnt_clr | 17 | rw | 0x0 |
Clear/reset for counter rdc_fifo_rst_err_cnt[3:0]. 0: no clear 1: clear Note: This is a synchronous dynamic signal that must have timing closed. |
| reg_phy_use_fixed_re | 16 | rw | 0x1 |
When 1: PHY generates FIFO read enable after fixed number of clock cycles as defined by reg_phy_rdc_we_to_re_delay[3:0]. When 0: PHY uses the not_empty method to do the read enable generation. Note: This port must be set HIGH during training/leveling process i.e. when ddrc_dfi_wrlvl_en/ ddrc_dfi_rdlvl_en/ ddrc_dfi_rdlvl_gate_en port is set HIGH. |
| reg_phy_rdc_fifo_rst_disable | 15 | rw | 0x0 | When 1, disable counting the number of times the Read Data Capture FIFO has been reset when the FIFO was not empty. |
| reserved | 14:12 | ro | 0x0 | Reserved |
| reg_phy_rdc_we_to_re_delay | 11:8 | rw | 0x2 |
This register value + 1 give the number of clock cycles between writing into the Read Capture FIFO and the read operation. The setting of this register determines the read data timing and depends upon total delay in the system for read operation which include fly-by delays, trace delay, clkout_invert etc. This is used only if reg_phy_use_fixed_re=1. |
| reg_phy_wr_cmd_to_data | 7:4 | rw | 0x0 | Not used in DFI PHY. |
| reg_phy_rd_cmd_to_data | 3:0 | rw | 0x0 | Not used in DFI PHY. |