This register's meaning varies according to the operating mode as follows:
* Master transmitter mode: number of data bytes still not transmitted minus one
* Master receiver mode: number of data bytes that are still expected to be received
* Slave transmitter mode: number of bytes remaining in the FIFO after the master terminates the transfer
* Slave receiver mode: number of valid data bytes in the FIFO
This register is cleared if CLR_FIFO bit in the control register is set.
| Field Name | Bits | Type | Reset Value | Description |
|---|---|---|---|---|
|
XIICPS_TRANS_SIZE_MASK (MASK) |
7:0 | rw | 0x0 |
Transfer Size 0-255 |