In statistics register block. Is reset to zero on a read and sticks at all ones when it counts to its maximum value. It should be read frequently enough to prevent loss of data.
For test purposes, it may be written by setting bit 7 (Write Enable) in the network control register. Setting bit 6 (increment statistics) in the network control register causes all the statistics registers to increment by one, again for test purposes.
Once a statistics register has been read, it is automatically cleared.
| Field Name | Bits | Type | Reset Value | Description |
|---|---|---|---|---|
| reserved | 31:10 | ro | 0x0 | Reserved, read as 0, ignored on write. |
| carrier_sense_errs | 9:0 | ro | 0x0 | Carrier sense errors - a 10 bit register counting the number of frames transmitted where carrier sense was not seen during transmission or where carrier sense was deasserted after being asserted in a transmit frame without collision (no under run). Only incremented in half duplex mode. The only effect of a carrier sense error is to increment this register. The behavior of the other statistics registers is unaffected by the detection of a carrier sense error. |