Register SLCR_LOCK Details - Register SLCR_LOCK Details - 1.15 English - UG585

Zynq 7000 SoC Technical Reference Manual (UG585)

Document_ID
UG585
Release_Date
2026-02-06
Version
1.15 English
Field Name Bits Type Reset Value Description
reserved 31:16 wo 0x0 Reserved. Writes are ignored, read data is zero.
LOCK_KEY 15:0 wo 0x0 Write the lock key, 0x767B, to write protect the slcr registers: all slcr registers, 0xF800_0000 to 0xF800_0B74, are write protected until the unlock key is written to the SLCR_UNLOCK register. A read of this register returns zero.